Negative Pressure Drainage Tube Set 3

Model Specifications:

Back type: 14Fr, 16Fr, 18Fr, 20Fr, 22Fr, 24Fr, 26Fr, 28Fr, 30Fr, 32Fr;

H type: 14Fr, 16Fr, 18Fr, 20Fr, 22Fr, 24Fr, 26Fr, 28Fr, 30Fr, 32Fr;

Cross type: 10Fr, 12Fr, 14Fr, 16Fr, 18Fr, 20Fr, 22Fr, 24Fr, 26Fr, 28Fr, 30Fr, 32Fr, 34Fr;

Round: 8Fr, 10Fr, 12Fr, 14Fr, 16Fr, 18Fr, 20Fr, 22Fr, 24Fr, 26Fr, 28Fr, 30Fr, 32Fr, 34Fr, 36Fr


Product name: 

Disposable negative pressure drainage tube set 3


Model Specifications:

Back type: 14Fr, 16Fr, 18Fr, 20Fr, 22Fr, 24Fr, 26Fr, 28Fr, 30Fr, 32Fr;

H type: 14Fr, 16Fr, 18Fr, 20Fr, 22Fr, 24Fr, 26Fr, 28Fr, 30Fr, 32Fr;

Cross type: 10Fr, 12Fr, 14Fr, 16Fr, 18Fr, 20Fr, 22Fr, 24Fr, 26Fr, 28Fr, 30Fr, 32Fr, 34Fr;

Round: 8Fr, 10Fr, 12Fr, 14Fr, 16Fr, 18Fr, 20Fr, 22Fr, 24Fr, 26Fr, 28Fr, 30Fr, 32Fr, 34Fr, 36Fr


Product Details:

Structure and composition: The product consists of a drainage tube, a guiding needle, a negative pressure ball, a drainage bag, a fixed sticker and a connecting component (including a conical joint, a connecting tube, and a two-way valve). Bags, fixing stickers and connecting components (including conical fittings, connecting pipes, and two-way valves) are optional accessories.

Scope of application: It is used to drain the patient's effusion, exudate or gas to the outside of the body; it is suitable for the drainage of pleural cavity, abdominal cavity, body surface or incision.

Product performance: Sterilized by ethylene oxide, the product is sterile. The residual amount of ethylene oxide in the product is not more than 10μg/g when leaving the factory.


Contraindications: 

Those who are allergic to silicone materials are disabled, and others are judged by clinicians.


Drainage tube features:

1. Imported medical grade silicone raw material, soft tube body, good biocompatibility, no irritation and sensitization;

2. The blue X-ray contrast line design is convenient to determine the exact position of the tube in the body.

3. The tube body is designed with positioning points, which is convenient to control the length of retention.

4. The tube body is integrally formed, without fracture or interface.

5. A variety of models and specifications to meet different clinical needs.

6. The long grooves of the cross-type, return-type, and H-type pipes in the drainage section make the drainage smoother when extubation is completed, avoid straining the patient's muscles during extubation, and greatly reduce the patient's pain.

7. The cross-type, return-type and H-type pipes have excellent kink resistance, and will not cause poor drainage due to pipe bending. At the same time, the excellent elasticity of the material can enable the pipe body to automatically restore its shape after being flattened, ensuring continuous assurance. Drain the flow smoothly.


Cross tube: 

The design of the cross-shaped tube body forms a drainage channel that is fully open in four directions, 360-degree all-round drainage, large drainage volume, high efficiency and good effect;


Return tube: 

The design of the return tube body, the three-chamber drainage mode, compared with the single drainage method, it is not easy to block the tube, and the drainage effect is good. There are two support columns in the tube, and the structure is more stable.


H-shaped tube: 

H-shaped tube body design, three-chamber drainage mode, compared with a single drainage method, it is not easy to block the tube, and the drainage effect is good. There are two support columns in the tube, and the structure is more stable.


Guide needle features:

1. Made of medical stainless steel, it is easy to puncture and the wound is small.

2. The curvature can be adjusted freely, suitable for a variety of surgical sites.

3. Clinical use is mostly used in orthopaedics; other departments are used depending on the surgeon's surgical experience and habits.


Negative pressure ball features:

1. Made of high-quality silicone rubber with excellent elasticity;

2. The material is transparent, which is convenient for medical staff to observe the amount, color and nature of the drainage fluid;

3. High drainage efficiency, continuous negative pressure suction can completely remove blood and exudate from the wound;

4. The one-way valve design can effectively prevent the backflow of drainage fluid;

5. According to clinical needs, configure a reasonable type of drainage tube, and rationally cut the horn-shaped drainage interface to increase the drainage cross-section to ensure smooth flow;

6. According to the size of the pipe diameter, use a scalpel to make a reasonable flat cut and position, and make sure that the drainage tube will not fall off after docking.


Fixed sticker features:

1. The ergonomic 30-degree angle design is convenient for patients to wear;

2. It adopts ultra-thin and comfortable new semi-permeable membrane, which has the characteristics of good waterproof, antibacterial, breathable and easy to use.

3. Good application performance, good exudate absorption and fixation effect.

4. Before use, keep the puncture site and surrounding skin clean and dry, especially after using iodophor on the body surface, and the application area of iodophor is less than the area of the fixed sticker. (Consider the viscous resistance of iodophor to the semipermeable membrane) During use, if adhesion occurs or folds occur when it is attached to the body surface, it is recommended to discard it.